Basic Info.
Wire Core Material
Red Copper Wire
Certification
ISO, CCC, CE
Model
AGRP
Brand
Bull Cable
Transport Package
Carton
Specification
Conductor nominal section mm2:0.75;1.0;1.5;2.5;4;6
Trademark
Bull
Origin
China
HS Code
854449210
Production Capacity
5000pieces/Years
Product Description


1. Rated voltage: Uo/U:3.6/6kV, 6/10kV(11kV), 12/20kV(24kV), 19/33kV, 26/35kV(35kV).
2. No. of core: Single-core or three cores.
3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. long-term is no more than 5 seconds). The highest temperature for a conductor is no more than 250ºC.
4. D.C. resistance of the conductor complies with the stipulations of 3.6/6kV, 6/10kV(11kV), 12/20kV(24kV), 19/33kV, 26/35kV(35kV).
5. The environment temperature should be no lower than 0oC when lay. Otherwise, it should be preheated.
6. The cable is laid without a horizontal drop limit.
7. Working Frequency Voltage Test: 3.5Uo/5min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.
9. Minimum Bending Radius: Single core - Fixed: 15 x overall diameter;3 core - Fixed: 12 x overall diameter
(Single core 12 x overall diameter and 3 core 10 x overall diameter where bands are positioned adjacent to joint or terminations provided that the bending is carefully controlled by the use of a former)
Note: The single-core armored cables are used for the D.C. system only. If used for the A.C. system, the magnetic isolation should be applied to the steel armor wires of non-magnetical materials that should be used.
0.6/1kV-3 core copper conductor XLPE insulated PVC sheathed power cable | |||||||
No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20ºC) | Current carrying capacity | |
(mm2) | (mm) | (mm) | (mm) | (kg/km) | Max. DC resistance of conductor(20ºC | In Air(A) | In Ground(A) |
3X1.5 | 0.7 | 1.8 | 11.8 | 135 | 12.1 | 21 | 30 |
3X2.5 | 0.7 | 1.8 | 12.7 | 180 | 7.41 | 28 | 39 |
3X4 | 0.7 | 1.8 | 13.8 | 225 | 4.61 | 37 | 51 |
3X6 | 0.7 | 1.8 | 14.9 | 300 | 3.08 | 47 | 64 |
3X10 | 0.7 | 1.8 | 17.2 | 430 | 1.83 | 65 | 86 |
3X16 | 0.7 | 1.8 | 19.4 | 630 | 1.15 | 84 | 110 |
3X25 | 0.9 | 1.8 | 22.8 | 940 | 0.727 | 110 | 140 |
3X35 | 0.9 | 1.8 | 25.0 | 1250 | 0.524 | 135 | 170 |
3X50 | 1.0 | 1.8 | 24.4 | 1500 | 0.387 | 170 | 205 |
3X70 | 1.1 | 1.9 | 29.4 | 2140 | 0.268 | 215 | 250 |
3X95 | 1.1 | 2.0 | 33.6 | 2960 | 0.193 | 265 | 300 |
3X120 | 1.2 | 2.1 | 35.9 | 3760 | 0.153 | 310 | 345 |
3X150 | 1.4 | 2.3 | 39.9 | 4420 | 0.124 | 350 | 385 |
3X185 | 1.6 | 2.4 | 44.1 | 5950 | 0.0991 | 405 | 435 |
3X240 | 1.7 | 2.6 | 51.1 | 7100 | 0.0754 | 480 | 500 |
3X300 | 1.8 | 2.7 | 56.1 | 9000 | 0.0601 | 555 | 565 |
3X400 | 2.0 | 3.0 | 62.4 | 10000 | 0.0470 | 640 | 640 |