Basic Info.
Model NO.
KVVRP-0.6/1KV 7x2.5 SQMM
Material Shape
Round Wire
Range of Application
Power Station
Certification
ISO9001, CE, CCC, RoHS, VDE, Kema
Brand
Shanghai Shenghua
Conductor
Flexible Copper Wire
Insulation
PVC
Shield
Copper Wire Braiding
Outer Sheath
PVC
Standard
IEC60227
Rated Voltage
600/1000V
Certificate
Kema,TUV
Bending Radius
20X Cable O.D
Test Voltage
3.5kv/5min
Insulation Color
White with No.1,2,3...
Jacket Color
Black
UV
Yes
Oil-Resistant
Yes
Sample
Free
Transport Package
2000m/Drum
Specification
7x2.5SQMM
Trademark
SHAN CABLE
Origin
Shanghai China
HS Code
8544492100
Production Capacity
9853km/Week
Product Description
Control Cable Multi-Core Copper Wire Braid Screen KVVRP-0.6/1KV 7x2.5 SQMM
Constructions
Conductor: Plain circular flexible copper conductor, conform to IEC 60228 class 5
Insulation: PVC/A
Fillers: PVC
Shield: Plain circular flexible copper wire braiding
Sheath: PVC
Note: Insulation color as per standards or at request
Applications
Suitable for use in power distribution lines or fixed installations or signal control with rated voltage up to 300/500kV indoor/outdoor, enclosed in conduit, in underground duct where not subject to mechanical damage.
Standards
China: GB/T 5023.2-2007
Technical data
Rated voltage: 300 / 500 kV
Max. Conductor Temp.: normal (70ºC), short circuit no more than 5 s (160ºC when section-area below 300mm2, 140ºC when section-area above 300mm2)
Min. Ambient Temp.: 0ºC, after installation and only when cable is in a fixed position
Min. Bending Radius: 20 x cable O.D
Certificates
CE, RoHS, CCC, KEMA and more others at request
Specifications
2 Cores
Constructions
Conductor: Plain circular flexible copper conductor, conform to IEC 60228 class 5
Insulation: PVC/A
Fillers: PVC
Shield: Plain circular flexible copper wire braiding
Sheath: PVC
Note: Insulation color as per standards or at request
Applications
Suitable for use in power distribution lines or fixed installations or signal control with rated voltage up to 300/500kV indoor/outdoor, enclosed in conduit, in underground duct where not subject to mechanical damage.
Standards
China: GB/T 5023.2-2007
Technical data
Rated voltage: 300 / 500 kV
Max. Conductor Temp.: normal (70ºC), short circuit no more than 5 s (160ºC when section-area below 300mm2, 140ºC when section-area above 300mm2)
Min. Ambient Temp.: 0ºC, after installation and only when cable is in a fixed position
Min. Bending Radius: 20 x cable O.D
Certificates
CE, RoHS, CCC, KEMA and more others at request
Specifications
2 Cores
Nom. cross-section of conductor | Max. Diameter of stranded Wire | Insulation Thickness | Copper wire diameter of shield | Sheath Thickness | Approx. O.D. mm | Max. D.C Resistance of Conductor | Min.Insulation Resistant at 70ºC | |
mm2 | mm | mm | mm | mm | Max. | Min. | (20 ºC ) Ω /km | MΩ •km |
1 × 0.08 | 0.13 | 0.4 | 0.10 | 0.4 | 2.4 | 2.9 | 247 | 0.018 |
1 × 0.5 | 0.21 | 0.5 | 0.10 | 0.4 | 3.1 | 3.8 | 39.0 | 0.012 |
1 ×1.0 | 0.21 | 0.6 | 0.10 | 0.6 | 4.1 | 4.9 | 19.5 | 0.010 |
1 ×1.5 | 0.26 | 0.6 | 0.10 | 0.6 | 4.3 | 5.2 | 13.3 | 0.009 |
1 ×2.5 | 0.26 | 0.7 | 0.15 | 0.6 | 4.9 | 6.0 | 7.98 | 0.008 |
2 × 0.08 | 0.13 | 0.4 | 0.1 | 0.4 | 3.2 | 4.2 | 247 | 0.018 |
2 × 0.3 | 0.16 | 0.5 | 0.15 | 0.6 | 4.8 | 6.2 | 69.2 | 0.014 |
2 × 0.4 | 0.16 | 0.5 | 0.15 | 0.6 | 5.1 | 6.6 | 48.2 | 0.013 |
2 × 0.5 | 0.21 | 0.5 | 0.15 | 0.6 | 5.3 | 6.8 | 39.0 | 0.012 |
2 × 0.75 | 0.21 | 0.5 | 0.15 | 0.6 | 5.8 | 7.4 | 26.0 | 0.010 |
2 × 1.0 | 0.21 | 0.6 | 0.15 | 0.6 | 6.4 | 8.2 | 19.5 | 0.010 |
2 × 1.5 | 0.26 | 0.6 | 0.15 | 0.8 | 7.3 | 9.2 | 13.3 | 0.009 |
Construction | |||||
Quotation No. | 9 | 10 | 11 | ||
Model No.: Cu/PVC/Fr-PVC-SB- 0.6/1kV CL5( Sqmm) | 2x1.0 | 3x1.0 | 3x1.5 | ||
1 | Conductor | ||||
Material | Flexible Copper Conductor | ||||
Type | Class 5 | ||||
No./Diameter before stranded | 32/0.2 mm | 32/0.2 mm | 30/0.25mm | ||
2 | Insulation | ||||
Material | PVC | ||||
COLOR | White+Number | ||||
Thickness | 0.8mm | 0.8mm | 0.8mm | ||
Minimum Insulation Thickness | 0.62mm | 0.62mm | 0.62mm | ||
3 | Copper Wire Braid Overall Screen | ||||
Material | Copper Wire | ||||
Shielding Braid Density | 80% Dia 0.12mm | ||||
4 | Overall Sheath | ||||
Material | Flame-retardant PVC (BLACK) | ||||
Thickness | 1.8mm | 1.8mm | 1.8mm | ||
Approx Overall Diameter | 10.6 | 11 | 11.8 | ||
Technical Data & Packing | |||||
1 | Rated voltage | 0.6/1 KV | |||
2 | Testing Voltage(5 minutes) | 3.5kV | |||
3 | Max. Resistance of Conductor D.C at 20ºC | 19.5 Ω/km | 19.5 Ω/km | 13.3 Ω/km | |
4 | Approx Weight | 135kg/km | 156kg/km | 174 kg/km | |
5 | Working Temp. of conductor | 70ºC | |||
6 | Short circuit 5s of conductor(max) | 160ºC | |||
7 | Min.Installation temp | >0ºC |